BWXVV - 0647-03 INTRON A 3-50 MU

  • MSDS: BWXVV
  • Manufacturer: SCHERING CORP
  • Product Name: 0647-03 INTRON A 3-50 MU
  • National Stock Number: 6505-01-246-3793
Product Identification

Product ID:0647-03 INTRON A 3-50 MU
MSDS Date:06/26/1993
FSC:6505
NIIN:01-246-3793
MSDS Number: BWXVV

Responsible Party
SCHERING CORP
2000 GALLOPING HILL RD
KENILWORTH, NJ 07033-5000
US

Emergency Phone: 908-298-5044

Info Phone: 908-298-5044

Cage: SCHER

Contractor
SCHERING CORP
KENILWORTH, NJ 07033-5000 US

Telephone: 908-298-5044

Cage: SCHER

Ingredients

GLYCINE; AMINOACETIC ACID; GLYCOLIXIR; HAMPSHIRE GLYCINE

CAS: 56-40-6

RTECS: MB7600000


INTERFERON .ALPHA.2B

CAS: 98530-12-2


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: MAY CAUSE SENSITIZATION
&/ALLERGIC REACTIONS IN THROAT &/LUNGS. SKIN/EYES: MAY CAUSE
IRRITATION. INTERFERON-MAY IMPAIR FERTILITY, MAY CAUSE ACUTE
SERIOUS HYPERSENSITIVITY REACTIONS. INTERF ERON EXPOSURE TO
PREGNANT WOMEN IS CAUTIONED AGAINST DUE TO OCCURANCE OF
ABORTIFICIENT EFFECTS IN ANIMAL STUDIES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: MAY CAUSE SENSITIZATION &/ALLERGIC
REACTIONS IN THROAT &/LUNGS. SKIN/EYES: MAY CAUSE IRRITATION.
INTERFERON-MAY IMPAIR FERTILITY, MAY CAUSE ACUTE SERIOUS
HYPERSENSITIVITY REACTIONS. INTERF ERON EXPOSURE TO PREGNANT WOMEN
IS CAUTIONED AGAINST DUE TO OCCURANCE OF ABORTIFICIENT EFFECTS IN
ANIMAL STUDIES.
Medical Cond Aggravated by Exposure:DEBILITATING MEDICAL CONDITIONS &
COAGULATION DISORDERS.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED. SKIN:
THOROUGHLY WASH EXPOSED AREA W/SOAP & WATER. EYES: FLUSH W/WATER
FOR 15 MINS. INGESTION: GIVE COPIOUS AMOUNTS OF WATER & INDUCE
VOMITING IF C ONSCIOUS. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:WATER, WATER SPRAY, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR SCBA & FULL PROTECTIVE CLOTHING. FIGHT
FIRE FROM SAFE DISTANCE/PROTECTED LOCATION. USE WATER SPRAY TO KEEP
EXPOSED CONTAINERS & EQUIPMENT COOL.

Accidental Release

Spill Release Procedures:MINIMIZE CONTACT W/MATERIAL. ISOLATE AREA.
WEAR APPROPRIATE RESPIRATORY PROTECTION & PROTECTIVE CLOTHING.
SQUEEGIE/SCOOP/ABSORB/USE A VACUUM TO CLEAN UP. CLEAN AREA W/AN
ALKALINE CLEANER/DETERGENT.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA.

Exposure Controls

Respiratory Protection:WEAR A HALF MASK RESPIRATOR W/ORGANIC VAPOR/ACID
GAS/HIGH EFFICIENCY CARTRIDGES FOR HANDLING MATERIAL IN BULK.
Ventilation:ADEQUATE LOCAL EXHAUST FOR USE OF MATERIAL IN BULK.
Protective Gloves:LATEX
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS
Other Protective Equipment:LAB COAT/UNIFORM
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH HANDS & FOREARMS AFTER EACH USE.
Supplemental Safety and Health
CHANGE RESPIRATOR CARTRIDGE AFTER 4 HOURS OF CONTINUOUS USE, UPON
DETECTION OF ODOR, AN INCREASE IN BREATHING RESISTANCE, EYE/NASAL
IRRITATION.

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, STRONG ACIDS & BASES.
Stability Condition to Avoid:OPEN FLAME & HIGH TEMPS.
Hazardous Decomposition Products:CO & CO2.

Disposal

Waste Disposal Methods:MATERIAL SHOULD BE DISPOSED IN AN
ENVIRONMENTALLY SOUND MANNER IAW/FEDERAL, STATE & LOCAL
REGULATIONS. INCINERATION IS PREFERRED DISPOSAL METHOD.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.